Features
Compatibility
|
Applications
General Description The ME-1001 Line Simulator is a highly accurate, programmable filter designed to simulate the attenuation versus frequency characteristics of the #22AWG (0.7mm) unshielded twisted-pair transmission wire commonly used in long distance telephone trunk lines in the US and around the world. The same wire is also found in office buildings and industrial complexes where it forms the backbone of PBX and LAN communication systems. By simulating 11kft (3.3km) of transmission line in 230ft (70m) increments, the ME-1001 offers a convenient and practical method of developing and testing communications equipment intended for use on this wire. Easy to use front panel controls set the ME-1001's simulated line length displayed in kFeet, Meters, or dB of Attenuation at either 772kHz for 1.544Mb/s applications or 1024kHz for 2.048Mb/s applications. Input and output line terminations are also user-selectable to correctly match the characteristic impedances of either 100W or 120W twisted-pair wire systems. A 75W BALUN connection is also provided. All ME-1001 functions can be computer controlled via a standard RS-232 serial port for automated test applications. Options include 19" rack mount chassis, battery back-up, and an internal noise mixer. |
Input
|
Output Sourcing Impedance ................... 100W/120W/75W, ±5%
|
| Attenuation
Characteristics Attenuation range at fo with display setting:
Frequency dependent attenuation simulates that of #22AWG (0.7mm) unshielded twisted-pair wire at 20ºC. The following indicates the relative attenuation (AR) verses frequency normalized at fo =772kHz.
The attenuation at any frequency, A(f), can be calculated as a function of the attenuation setting at fo=772kHz as follows: A(f) = AR(f) X A(fo) |
. Attenuation adjustment step size with display setting:
CLICK ON GRAPH TO ENLARGE |
| Attenuation
Accuracy Attenuation tolerance at fo with display setting:
Attenuation tolerance at all other frequencies relative to fo is given by the following graph: |
CLICK ON GRAPH TO ENLARGE |
General
Specifications
|
Ordering
Information
|